DOW Filmtec LE-4040 RO Membrane 2500 GPD
DOW Filmtec LE-4040 RO Membrane 2500 GPD, a 4" x 40" brackish water Reverse Osmosis Membrane that can provide RO quality water up to 2,500 gallons per day at a 15% recovery rate. It can operate at feed pressures ranging from 150 psi to 600 psi with 99.0% salt rejection. This element offers the highest quality water for medium-sized water treatment system that produce less than approximately 10 gpm (2300 L/h) of permeate. This membrane element features the thickest feed spacer (34 mil) available in the industry today to lessen the impact of fouling as well as a fiberglass shell.
This product has been discontinued several years ago by the manufacturer. show more
DOW Filmtec LE-4040 RO Membrane 2500 GPD, a 4" x 40" brackish water Reverse Osmosis Membrane that can provide RO quality water up to 2,500 gallons per day at a 15% recovery rate. It can operate at feed pressures ranging from 150 psi to 600 psi with 99.0% salt rejection. This element offers the highest quality water for medium-sized water treatment system that produce less than approximately 10 gpm (2300 L/h) of permeate. This membrane element features the thickest feed spacer (34 mil) available in the industry today to lessen the impact of fouling as well as a fiberglass shell.
This product has been discontinued several years ago by the manufacturer. The closest new membrane is LCLE-4040.
Filmtec RO elements separate salts from water and are produced with an automated fabrication process for precision, consistency, and reliability offering high rejection of dissolved solids and organics and operate very efficiently at lower pressures. These Filmtec Tap Water Thin Film-Commercial RO membranes have a hard shell exterior making them suitable and recommended for systems with multiple-element housings containing three or more membranes, as they are designed to withstand higher pressure drops. In addition to the highest quality water and the lowest energy costs, DOW membranes also deliver savings by providing the industry’s longest lasting and most reliable performance membranes due to increased resistance to fouling.
This membrane is a part of the "Fiberglassed Elements for Light Industrial Systems" by DOW FILMTEC and are primarily applied in commercial water demineralization and commercial water treatment systems. Its advanced technological design is manufactured for excellent structural stability and more productivity than other elements.
Filmtec RO elements separate salts from water and are produced with an automated fabrication process for precision, consistency, and reliability offering high rejection of dissolved solids and organics and operate very efficiently at lower pressures. These Filmtec Tap Water Thin Film-Commercial RO membranes have a hard shell exterior making them suitable and recommended for systems with multiple-element housings containing three or more membranes, as they are designed to withstand higher pressure drops. In addition to the highest quality water and the lowest energy costs, DOW membranes also deliver savings by providing the industry’s longest lasting and most reliable performance membranes due to increased resistance to fouling.
This membrane is a part of the "Fiberglassed Elements for Light Industrial Systems" by DOW FILMTEC and are primarily applied in commercial water demineralization and commercial water treatment systems. Its advanced technological design is manufactured for excellent structural stability and more productivity than other elements.
Key Features and Benefits:

- 2,500 Gallons per day.
- 34 mil feed spacer.
- 600 psi maximum operating pressure.
- Removes chemical contaminants.
- Reduce wastewater volumes by increasing water reuse.
- High performance at low pressure resulting in less energy usage and lower costs.
- Durable with Good Cleanability for Long Element Life.
- DOW FilmTec high quality, long lasting and reliable performance.
Specifications
Model/SKU:DWC21Manufacturer ID(Part#):LE-4040 (Part #275173 )Dimensions(Diameter x Length):4" x 40" (actual 3.9" x 40")Stabilized Salt Rejection:99.0%Permeate Flow Rate(Gallons per Day, gpd):2,500 gpd(9,500 L/Day or 9.5 m3/day) *Maximum Feed Flow Rate(Gallons per Minute, gpm):16.0 gpm (3.6 m3/h)Applied Pressure(psi):150 psi (10.3 bar)Maximum Operating Pressure(psi):600 psi (41 bar)Maximum Pressure Drop(psi):15 psi (0.9 bar)Maximum Operating Temperature(°F):113°F (45°C)pH Range, Continuous Operation:2 - 11 **pH Range, Short-Term Cleaning:1 - 13Maximum Feed Silt Density Index(SDI):SDI 5Free Chlorine Tolerance(ppm):< 0.1 ppm ***Membrane Style:Drop-in ElementMembrane Material:Polyamide Thin-Film CompositeActive Area:78 sq. ft.Outer Wrap:Hard fiberglass outer shellHousing/Pressure Vessel Size(inch):4 inch* Permeate flow rate and salt rejection based on the following test conditions: 2000 ppm NaCl, 150 psi (10.3 bar), 77°F(25°C), 15% recovery. Permeate flow rates for individual elements may vary +/-20%.
**Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
*** Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow recommends removing residual free chlorine by pretreatment prior to membrane exposure. Most RO systems have carbon pre-filters for this purpose.
**Maximum temperature for continuous operation above pH 10 is 95°F (35°C).
*** Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow recommends removing residual free chlorine by pretreatment prior to membrane exposure. Most RO systems have carbon pre-filters for this purpose.
PRODUCT NOTES:
- LE-4040 replaces BW30LE-4040.
- Proper start-up of reverse osmosis water treatment system is essential to prepare the industrial membrane elements for operating service and to prevent membrane damage due to overfeeding or hydraulic shock.
- Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.
- During prolonged system shutdowns, it is recommended that the Dow Filmtec membrane elements be immersed in a preservative solution. This is to prevent biological growth.
- (To ensure proper product startup and usage, please review Operation Guidelines and General Information section from the Product Data Sheet.)
- LE-4040 replaces BW30LE-4040.
- Proper start-up of reverse osmosis water treatment system is essential to prepare the industrial membrane elements for operating service and to prevent membrane damage due to overfeeding or hydraulic shock.
- Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.
- During prolonged system shutdowns, it is recommended that the Dow Filmtec membrane elements be immersed in a preservative solution. This is to prevent biological growth.
- (To ensure proper product startup and usage, please review Operation Guidelines and General Information section from the Product Data Sheet.)